ABB 1TGE120010R1300控制保护电机启动单元原产地瑞士,2023年7月20日江西现货10台。
ABB 1TGE120010R1300控制保护电机启动单元主要有以下功能:
- 启动和停止控制:控制保护电机启动单元可以实现电动机的安全启动和停止,包括直接启动、反转启动、星-三角启动等不同启动方式的控制。
- 过载保护:该单元可以监测电动机的电流,并在电流超过设定值时采取保护措施,如断开电源或发出警报,以防止电动机过载运行。
- 短路保护:控制保护电机启动单元可以检测电动机回路中的短路情况,并及时断开电源,以保护电动机和系统的安全。
- 过压保护和欠压保护:单元可以监测电动机供电电压的变化,并在电压超过或低于设定范围时采取保护措施,以防止电动机受到损坏。
- 缺相保护:如果电动机供电中出现缺相情况(某个相线失去电压),控制保护电机启动单元可以检测到并采取相应的保护措施,以避免电动机受损。
- 延时启动和停止:单元可以设置启动和停止的延时,以满足特定应用中的要求,避免突然的启动或停止对系统造成冲击。
- 通信和监控功能:一些控制保护电机启动单元具有通信接口,可以与上位系统进行通信,并传输电动机的状态和数据信息,实现远程监控和控制。
The ABB 1TGE120010R1300 control and protection motor starting unit mainly has the following functions:
Start and stop control: The control protection motor start unit can achieve safe start and stop of the motor, including direct start, reverse start, star delta start, and other different start methods.
Overload protection: This unit can monitor the current of the motor and take protective measures when the current exceeds the set value, such as disconnecting the power supply or issuing an alarm, to prevent the motor from overload operation.
Short circuit protection: The control protection motor starting unit can detect short circuits in the motor circuit and timely disconnect the power supply to protect the safety of the motor and system.
Over voltage protection and under voltage protection: The unit can monitor changes in the motor supply voltage and take protective measures when the voltage exceeds or falls below the set range to prevent damage to the motor.
Phase loss protection: If a phase loss occurs in the power supply of the motor (a certain phase line loses voltage), the control protection motor starting unit can detect and take corresponding protective measures to avoid motor damage.
Delayed start and stop: The unit can set the delay for start and stop to meet the requirements of specific applications and avoid sudden start or stop causing impact on the system.
Communication and monitoring functions: Some control and protection motor starting units have communication interfaces that can communicate with the upper system and transmit motor status and data information, achieving remote monitoring and control.
Start and stop control: The control protection motor start unit can achieve safe start and stop of the motor, including direct start, reverse start, star delta start, and other different start methods.
Overload protection: This unit can monitor the current of the motor and take protective measures when the current exceeds the set value, such as disconnecting the power supply or issuing an alarm, to prevent the motor from overload operation.
Short circuit protection: The control protection motor starting unit can detect short circuits in the motor circuit and timely disconnect the power supply to protect the safety of the motor and system.
Over voltage protection and under voltage protection: The unit can monitor changes in the motor supply voltage and take protective measures when the voltage exceeds or falls below the set range to prevent damage to the motor.
Phase loss protection: If a phase loss occurs in the power supply of the motor (a certain phase line loses voltage), the control protection motor starting unit can detect and take corresponding protective measures to avoid motor damage.
Delayed start and stop: The unit can set the delay for start and stop to meet the requirements of specific applications and avoid sudden start or stop causing impact on the system.
Communication and monitoring functions: Some control and protection motor starting units have communication interfaces that can communicate with the upper system and transmit motor status and data information, achieving remote monitoring and control.
Brand: ABB
Model: 1TGE120010R1300
Product Name: Control Protection Motor Starting Unit
Product net width: 53mm
Product net height: 125mm
Product net depth/length: 260mm
Net weight of product: 0.7 kilograms
order
Minimum order quantity: 1 piece
Origin: Switzerland
There are no reviews yet.